Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Korean Journal of Anesthesiology ; : 19-23, 2011.
Article in English | WPRIM | ID: wpr-171794

ABSTRACT

BACKGROUND: The Glidescope(R) videolaryngoscope is a new device for tracheal intubation that provides an improved view of the larynx. This study was performed to compare the Glidescope with the McGrath videolaryngoscope in terms of time to intubation (TTI) and number of attempts. METHODS: Patients were randomly allocated to one of two groups, Glidescope or McGrath group, by using computer-generated numbers. Tracheal intubation was attempted by an anesthesiologist with extensive experience using these two devices. The operator recorded ease of visualization of glottic structures based on the classification described by Cormack and Lehane. Number of failures, number of attempts and their duration, total intubation time, and events during the whole procedure were recorded. The duration of one attempt was defined as the time elapsed between picking up the endotracheal tube and verification of tracheal intubation with visualization of three expiratory carbon dioxide waveforms. TTI was defined as the sum of the duration of all intubation attempts (as many as three), excluding preoxygenation procedures. RESULTS: TTI was significantly shorter for the Glidescope(R) compared to the McGrath(R) laryngoscope (40.5 vs. 53.3 s, respectively, P < 0.05). However, glottic views obtained at intubation were similar between the two groups. Number of intubation attempts was not significantly different between the two groups (1.03 +/- 0.19 vs 1.10 +/- 0.32, respectively) (mean +/- SD). CONCLUSIONS: Study results demonstrated that the Glidescope reduced total intubation time in comparison with the McGrath, in terms of TTI in patients with normal airways.


Subject(s)
Humans , Carbon Dioxide , Intubation , Laryngoscopes , Larynx
2.
Korean Journal of Anesthesiology ; : 50-54, 2011.
Article in English | WPRIM | ID: wpr-171789

ABSTRACT

BACKGROUND: The greater occipital nerve (GON) block has been frequently used for different types of headache, but performed with rough estimates of anatomic landmarks. Our study presents the values of the anatomic parameters and estimates the effectiveness of the ultrasound-guided GON blockade. METHODS: The GON was detected using ultrasound technique and distance from external occipital protuberance (EOP) to GON, from GON to occipital artery and depth from skin to GON was measured in volunteers. Patients with occipital headache were divided into two groups (ultrasound-guided block: group S, conventional blind block: group B) and GON block was performed. The same parameters were measured on group S and VAS scores were assessed at pretreatment, 1 week and 4 weeks after treatment on both groups. RESULTS: The GON had distance of 23.1 +/- 3.4 mm (right) and 20.5 +/- 2.8 mm (left) from EOP to GON. Its depth below the skin was 6.8 +/- 1.5 mm (right) and 7.0 +/- 1.3 mm (left). The distance from GON to occipital artery was 1.5 +/- 0.6 mm (right) and 1.2 +/- 0.6 mm (left) in volunteers. Initial VAS score of group S and group B patients were 6.4 +/- 0.2 and 6.5 +/- 0.2. VAS score of 4 weeks after injection were 2.3 +/- 0.2 on group S and 3.8 +/- 0.3 on group B (P = 0.0003). CONCLUSIONS: The parameters measured in this study should be useful for GON block and ultrasound-guided blockade is likely to be a more effective technique than blind blockade in occipital headache treatment.


Subject(s)
Humans , Anatomic Landmarks , Arteries , Follow-Up Studies , Headache , Nerve Block , Skin
3.
Korean Journal of Anesthesiology ; : 167-172, 2011.
Article in English | WPRIM | ID: wpr-219329

ABSTRACT

BACKGROUND: Several publications have reported the successful, safe use of Laryngeal Mask Airway (LMA)-Classic devices in patients undergoing laparoscopic surgery. However, there have been no studies that have examined the application of volume-controlled ventilation (VCV) or pressure-controlled ventilation (PCV) using a LMA during gynecological laparoscopy. The aim of this study is to compare how the VCV and PCV modes and using a LMA affect the pulmonary mechanics, the gas exchange and the cardiovascular responses in patients who are undergoing gynecological laparoscopy. METHODS: Sixty female patients were randomly allocated to one of two groups, (the VCV or PCV groups). In the VCV group, baseline ventilation of the lung was performed with volume-controlled ventilation and a tidal volume of 10 ml/kg ideal body weight (IBW). In the PCV group, baseline ventilation of the lung using pressure-controlled ventilation was initiated with a peak airway pressure that provided a tidal volume of 10 ml/kg IBW and an upper limit of 35 cmH2O. The end-tidal CO2, the peak airway pressures (Ppeak), the compliance, the airway resistance and the arterial oxygen saturation were recorded at T1: 5 minutes after insertion of the laryngeal airway, and at T2 and T3: 5 and 15 minutes, respectively, after CO2 insufflation. RESULTS: The Ppeak at 5 minutes and 15 minutes after CO2 insufflation were significantly increased compared to the baseline values in both groups. Also, at 5 minutes and 15 minutes after CO2 insufflation, there were significant differences of the Ppeak between the two groups. The compliance decreased in both groups after creating the pneumopertoneim (P < 0.05). CONCLUSIONS: Our results demonstrate that PCV may be an effective method of ventilation during gynecological laparoscopy, and it ensures oxygenation while minimizing the increases of the peak airway pressure after CO2 insufflation.


Subject(s)
Female , Humans , Airway Resistance , Compliance , Ideal Body Weight , Insufflation , Laparoscopy , Laryngeal Masks , Lung , Mechanics , Oxygen , Tidal Volume , Ventilation
4.
The Korean Journal of Critical Care Medicine ; : 266-270, 2010.
Article in Korean | WPRIM | ID: wpr-648809

ABSTRACT

Reexpansion pulmonary edema (RPE) is a rare but sometimes fatal complication of the treatment of lung collapse secondary to pneumothorax, pleural effusion, or atelectasis. We experienced a case of RPE that developed following decortication. A 46 year-old female had a decortication for pyothorax under one-lung anesthesia. There was no event during the operation and results of arterial blood gas analysis were within normal limits. After the operation, tracheal extubation was performed and 100% oxygen saturation on a pulse oximeter (SpO2) was maintained with 100% O2, (8 L/min) via mask ventilation with self-respiration. The patient, with 50% Venturi mask, was transported to the intensive care unit (ICU). On arrival at the ICU, a SpO2 of 80% was detected and arterial blood gas analysis revealed hypoxemia with acute hypercapnic respiratory acidosis. Fortunately, reexpansion pulmonary edema was detected early and intensive treatment was performed using mechanical ventilation with positive end-expiratory pressure. Tracheal extubation was performed after 1 day of mechanical ventilation. The reexpansion pulmonary edema was successfully treated and the patient recovered without any complications.


Subject(s)
Female , Humans , Acidosis, Respiratory , Airway Extubation , Anesthesia , Hypoxia , Blood Gas Analysis , Empyema, Pleural , Intensive Care Units , Masks , Oxygen , Pleural Effusion , Pneumothorax , Positive-Pressure Respiration , Pulmonary Atelectasis , Pulmonary Edema , Respiration, Artificial , Ventilation
SELECTION OF CITATIONS
SEARCH DETAIL